Cat C32 ACERT Tier 3
C32 ACERT generator sets incorporate a separate circuit aftercooling system (SCAC) for all configurations. The primary advantage of the SCAC systsem is reduced aftercooler corrosion since no sea water circulates through the aftercooler. Many other improvements on these engines contribute to minimizing owning and operating costs. The EPA Tier 3, IMO II, EU Stage IIIA compliant ratings are available with heat exchanger or keel cooled options. Heat exchanger configurations have an optional front mounted sea water pump.
Specifications
Generator Set Specifications
Minimum Rating | 730 ekW (913 kVA) |
Maximum Rating | 940 ekW (1175 kVA) |
Frequency | 60hz |
Speed | 1800 rpm |
Emissions/Fuel Strategy | EPA Tier III |
Engine Specifications
Aspiration | Turbocharged and aftercooled |
Bore | 145 mm |
Stroke | 162 mm |
Displacement | 32.1 l |
Governor Type | Electronic |
Fuel System | MEUI |
Engine Model | Vee-12, 4-stroke-Cycle-Diesel |
Generator Set Dimensions
Width | 1528 mm |
Height | 1667 mm |
Weight - Estimated | 7131 kg |
Length | 162.8 in/4271 mm (minimum), 175.3 in/4452 mm (maximum) |
Generator Specifications
Excitation | Permanent magnet |
Number of Poles | 4 |
Number of Bearings | 2 roller bearings |
Number of Leads | 6 |
Insulation | Class H |
IP Rating | 23 |
Voltage Regulator | CDVR |
Benefits & Features
Emissions
U.S. EPA Tier 3 compliant
Worldwide support
Extensive service network of dealers; Unparalleled service from authorized marine dealers
Durability
Proven engine operating history; Performance iron with thousands of hours of validation testing for quality and durability
Reliability
60 months standard warranty
Cooling system
Heat Exchanger or Keel Cooling; Heat exchanger configurations: optional front mounted sea water pump
Aftercooling system
Separate circuit aftercooling system (SCAC): no seawater circulating through the aftercooler